Verifications & Calibrations of Dosimeters and Measuring Devices
We ensure the precise calibration and verification of your measuring devices — so that your measurement results are reliable and compliant with standards.
Accurate and traceable calibrations are a key requirement for reliable radiation measurements and reliable radiation protection.
Seibersdorf Labor GmbH operates an accredited calibration laboratory for ionizing radiation and offers calibrations for a wide range of dosimeters and radiation measuring devices.
Our calibrations ensure metrological traceability to national standards and meet the requirements of applicable radiation protection and quality regulations.
We offer calibrations and verifications for various measuring devices to determine dose and dose rate.
These include:
Calibration is carried out under controlled conditions in our accredited measurement laboratories.
For medical applications — particularly in radiology and radiotherapy — we also calibrate dosimeters for:
These verifications and calibrations support the quality assurance of medical radiation applications.
Various reference radiation fields are available for calibrating and testing dosimeters and measuring devices.
These include:
The reference radiation fields enable precise and reproducible verification and calibration conditions for various measurement tasks.
The calibrations made by Seibersdorf Labor GmbH are metrologically traceable.
Our calibration laboratory is:
Our calibrations therefore meet the highest standards of measurement accuracy and international comparability.
We offer you the opportunity to have your dosimeters calibrated on the dates listed below (X-ray therapy using soft and hard radiation only in ET3 and ET5).
| ET | Deadline for entries | Returns |
|---|---|---|
| 2026 | ||
| ET 1 | Tue, 27 January 2026 | approx. 4 weeks after the closing date |
| ET 2 | Tue, 24. March 2026 | approx. 4 weeks after the closing date |
| ET 3 | Tue, 26. May 2026 | approx. 4 weeks after the closing date |
| ET 4 | Tue, 25. August 2026 | approx. 4 weeks after the closing date |
| ET 5 | Tue, 27. October 2026 | approx. 4 weeks after the closing date |
Please refer to our current price list!
The price for calibration includes the following services:
Please note the comments at the end of the price list!
Since July 1, 2006, these types of measuring devices (radiation protection dosimeters other than fixed measurement systems, therapy dosimeters, diagnostic dosimeters except dosimeters for mammography, dosimeters for consistency testing except dosimeters for mammography) have been calibrated exclusively by accredited or authorized verification bodies; instead of BEV, we carry out calibrations in accordance with our scope of authorization and in accordance with the Measurement and Calibration Act in connection with the provisions of the Calibration Center Ordinance and the Accreditation Act by.
Every dosimeter that is used or kept available in traffic subject to verification must be calibrated every 2 years. The verification stamp shows the last three digits of the year in which the calibration was carried out. The expiration of the subsequent submission period is stated in the verification certificate. In addition, an information sticker with the year for the next calibration is affixed to the dosimeter.
It is recommended that you submit the application for calibration during the year but no later than October. We are required to make an appointment for the calibration within 2 months. If a declaration for verification is filed in December, but we are unable to fulfill this order by the end of the year, the measuring device should no longer be used in traffic subject to verification.
Each calibration body can freely set its prices based on commercial aspects. The Calibration Fees Ordinance only applies to the Verification Authority (BEV). The BEV prices for calibrations have remained unchanged since 1999.
In this case, the calibration cannot be carried out. The verification is clearly marked and rejected. The measuring device may be used until the current recalibration period has expired if the traffic error limits are met. There are also costs for an unsuccessful calibration, which can be found in our price list.
The dosimeter is obviously damaged or defective; type plate or approval designations are not available, illegible or incorrect; serial number, software version, device inscriptions, etc. do not meet the requirements for type approval; the operating instructions and necessary accessories were not included.
As an authorized verification agency, we issue a verification certificate for every successful calibration. This is, on the one hand, a confirmation of the calibration carried out and an internationally recognized test certificate for the metrological traceability of measuring devices within the framework of quality standards. For rejected dosimeters, we will issue one on request in accordance with the information sheet, which explains the reason for the rejection.
The following signs are affixed to the dosimeters: verification stamp, security stamp, possibly a protocol number and a sticker with an indication of the next calibration. Removing or manipulating the verification stamp, security stamp or protocol number expires the calibration for the device and it may no longer be used in traffic subject to verification. For this reason, the stamps are designed in such a way that they destroy themselves when removed.
Please contact us (see “Contact” section), we will be happy to help you! The BEV (www.metrologie.at) is also still available as a point of contact.